Zylox-tonbridge Medical Technology Co., Ltd. Company Logo Zylox-tonbridge Medical Technology Co., Ltd.

Thrombite Clot Retriever Device

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Browse by Category

Contact us

Zylox-tonbridge Medical Technology Co., Ltd.
[China]

Address
No. 270, Shuyun Road, Cangqian Street Hangzhou Zhejiang
Phone
86-0571-88610082
Contact name
Zylox

Quick Information

  • Place of Origin: China
  • :

Description

OVERVIEW Thrombite™ Clot Retriever Device HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE

The Thrombite™ endovascular clot retrieval   , featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

 

PRODUCT FEATURES

HELICAL OPEN-SIDE STRUCTURE

 

enables Thrombite™ clot retriever  to efficiently entwine and clamp the clot

 

assures clot retention for confident removal and revascularization

 

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

 

increases contact surface with thrombus and maximizes clot integration

 

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

 

optimizes clot retention during smooth navigation through the tortuous anatomies

 

Radiopaque markers on the distal end of the device increase device visibility

3 markers for the sizes with 3.0 and 4.0mm diameter

 

4 markers for the sizes with 5.0 and 6.0mm diameter

 

Advanced stent surface treatment process

RADIAL FORCE

High radial force is designed for clot integration at the initial stage of stent expansion

 

Low radial force at nominal stent diameter ensures atraumatic retrieval

 

RADIAL FORCE

How a Stent Retriever Procedure Is Performed Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retrieval device will be extracted along with the clot and finally leave your body. ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE STENT RETRIEVAL DEVICE STRUCTURE Thrombite™ Product code Diameter D(mm) Recommended Vessel Diameter(mm) Recommende Microcatheter ID (inch) Working Length A(mm) Stent Length B(mm) System Length(mm) Min. Max. 3MM CRD-3-15 3 1.5 3 0.21 15 27 1900 CRD-3-20 3 1.5 3 0.21 20 32 1900 CRD-3-25 3 1.5 3 0.21 25 37 1900 CRD-3-30 3 1.5 3 0.21 30 42 1900 4MM CRD-4-15 4 2 4 0.21 15 27 1900 CRD-4-20 4 2 4 0.21 20 32 1900 CRD-4-25 4 2 4 0.21 25 37 1900 CRD-4-30 4 2 4 0.21 30 42 1900 5MM CRD-5-15 5 2.5 5 0.027 15 27 1900 CRD-5-20 5 2.5 5 0.027 20 32 1900 CRD-5-25 5 2.5 5 0.027 25 37 1900 CRD-5-30 5 2.5 5 0.027 30 42 1900 6MM CRD-6-15 6 3 5.5 0.027 15 27 1900 CRD-6-20 6 3 5.5 0.027 20 32 1900 CRD-6-25 6 3 5.5 0.027 25 37 1900 CRD-6-30 6 3 5.5 0.027 30 42 1900 INDICATIONS Thrombite™ Clot Retriever Device The Thrombite™ clot retrieval device is intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Zylox Tonbridge  Medical highlights the corporate social responsibility and mission, and boosts the innovation and technological development by taking active part in the combination of scientific innovation with medical engineering.



Product Image

  • Thrombite Clot Retriever Device image

Related products from premium suppliers on EC21

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Zylox
Zylox-tonbridge Medical Technology Co., Ltd.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Physical Therapy Equipment
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838